{"id":10769,"date":"2026-09-22T13:08:17","date_gmt":"2026-09-22T11:08:17","guid":{"rendered":"https:\/\/solar-motors.com\/?post_type=product&#038;p=10769"},"modified":"2026-09-29T00:05:04","modified_gmt":"2026-09-28T22:05:04","slug":"sm4-bldc-sl-heavy-duty-solar-tracker-actuator","status":"publish","type":"product","link":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/","title":{"rendered":"SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR (0094-23)"},"content":{"rendered":"<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The SAT CONTROL SM4 BLDC-SL is a heavy-duty linear actuator specifically developed for solar tracking systems and other demanding outdoor positioning applications requiring high static holding capacity, reliable operation under wind loads, high-duty operation and long service life. The actuator combines a sensorless brushless DC motor, high-ratio planetary gearbox and a robust trapezodial stainless-steel spindle bronze nut transmission. The BLDC-SL drive eliminates mechanical brushes and provides substantially improved durability, thermal performance and duty-cycle capability compared with conventional brushed DC drives. The actuator has been specifically designed around the actual operating conditions of solar trackers &#8211; long periods of stationary holding, short tracking movements and occasional high transient loads caused by rapidly increasing wind conditions.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">25 kN Static Holding Capacity | 60% Duty Cycle | Sensorless Brushless Drive<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">1. KEY FEATURES<\/span><\/strong><\/span><\/p>\n<ul>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">24 VDC sensorless BLDC-SL motor<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">No Hall sensors required<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">No mechanical brushes &#8211; reduced wear and maintenance<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Maximum Static Holding Load up to 25 kN \/ 2,500 kgf tested to 37KN<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Three planetary gearbox ratios: 188.611 : 1 \/ 368.763 : 1 \/ 515.630 : 1<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Stainless-steel trapezoidal spindle<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Bronze spindle nut<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Heavy-duty EP lubrication with 5% MoS\u2082<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Duty Cycle: 60%<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Successfully tested at 83.3% duty cycle under high-load \/ maximum-power conditions<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">High short-duration thrust reserve for transient wind loads<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Continuous motor-current monitoring with SAT CONTROL positioner<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Designed specifically for solar trackers and demanding outdoor applications<\/span><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Ordering Codes:<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Select: <\/span><\/strong><a href=\"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/ChatGPT-Image-28.-sep.-2026-10_40_18.png\">Ordering Codes<\/a><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\" style=\"color: #008ccd\">2. THREE DRIVE CONFIGURATIONS<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The SM4 BLDC-SL actuator is available with three planetary gearbox ratios, allowing the drive to be optimized according to the required balance between movement speed and available thrust.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"151\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Parameter<\/span><\/strong><\/td>\n<td width=\"151\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">R188 &#8211; Higher Speed<\/span><\/strong><\/td>\n<td width=\"151\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">R369 &#8211; Balanced<\/span><\/strong><\/td>\n<td width=\"151\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">R516 &#8211; High Thrust<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Gear Ratio<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">188.611:1<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">368.763:1<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">515.630:1<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Operating Thrust<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">2.45 kN \/ 250 kgf<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">3.92 kN \/ 400 kgf<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">5.39 kN \/ 550 kgf<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Max Power Dynamic Thrust<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">4.90 kN \/ 500 kgf<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">7.85 kN \/ 800 kgf<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">10.79 kN \/ 1,100 kgf<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak Dynamic Thrust*<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">9.41 kN \/ 960 kgf<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">14.51 kN \/ 1480 kgf<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">19.94 kN \/ 2034 kgf<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Maximum Static Holding Load<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">25 kN \/ 2,550 kgf<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">25 kN \/ 2,550 kgf<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">25 kN \/ 2,550 kgf<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Approx. Rated Linear Speed<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">1.80 mm\/s<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">0.92 mm\/s<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">0.66 mm\/s<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Motor Current<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">3 A<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">3 A<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">3 A<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Maximum Motor Current<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">5.3 A<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">5.3 A<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">5.3 A<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Duty Cycle<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">60%<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">60%<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">60%<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Spindle Lead<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">4 mm<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">4 mm<\/span><\/td>\n<td width=\"151\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">60%<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">* Peak Dynamic Thrust is a short-duration (few seconds) drive capability and shall not be used as the normal or continuous operating point.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\" style=\"color: #008ccd\">3. LOAD DEFINITIONS<\/span><\/strong><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">RATED OPERATING THRUST<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Operating Thrust represents the recommended actuator thrust for normal repetitive operation. The solar tracker drive system should normally be designed to operate within this load range. Operation within the rated range provides substantial reserve for temporary increases in external loading.<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">PEAK DYNAMIC THRUST<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak Dynamic Thrust represents the short-duration drive capability available for transient load conditions. This additional thrust reserve is particularly important when wind loading increases rapidly while the solar tracker is still moving toward its horizontal or designated wind-stow position. Over the Max Power Dynomic Trust regions is not permited for a long time, mean that higher is the trust shorter is the permited time stays in that dangeros zone due to over-heating.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak Dynamic Thrust is NOT a rated or continuous operating load.<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">It shall not be used as the normal design operating point. Operation in the Peak Dynamic Thrust region should be limited to short-duration transient conditions and supervised by the drive electronics.<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">MAXIMUM STATIC HOLDING LOAD<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">25 kN \/ 2,550 kgf<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Maximum Static Holding Load defines the permissible stationary holding load of the actuator and does not represent the available motor-driven thrust. Static holding with the motor de-energized does not constitute motor duty and therefore does not contribute to the specified motor duty cycle. This distinction is particularly important in solar tracker applications. The actuator remains stationary for the majority of its operating life while mechanically maintaining the required tracker position. The high static holding capacity therefore provides substantial structural load capability without requiring the electric motor to continuously generate the corresponding force.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">4. DESIGNED FOR SOLAR TRACKER LOAD CONDITIONS<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Solar tracker actuators operate under substantially different conditions from conventional continuously operating industrial linear drives. During normal solar tracking, actuator movement is intermittent and relatively short. For the majority of the operating time, the actuator remains stationary and mechanically maintains the required tracker position. Under normal conditions, the actuator operates within its Rated Operating Thrust range. During rapidly increasing wind conditions, significantly higher dynamic forces may temporarily occur before the tracker reaches its horizontal or designated wind-stow position. The SM4 BLDC-SL actuator has therefore been designed around three clearly separated operating conditions:<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">NORMAL TRACKING<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-start\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Operating Thrust, Max Power Dynamic Trust<\/span><\/strong><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">TRANSIENT WIND LOAD \/ STOW MOVEMENT<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak Dynamic Thrust<\/span><\/strong><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">STATIONARY WIND LOAD<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Maximum Static Holding Load up to 25 kN \/ 2,550 kgf<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">This design philosophy provides <\/span><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">efficient normal operation<\/span> <span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">together with substantial mechanical and drive reserve for demanding outdoor conditions.<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">5. BLDC-SL SENSORLESS BRUSHLESS DRIVE<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">One of the major improvements of the new SM4 actuator generation is the BLDC-SL sensorless brushless motor. Unlike conventional brushed DC motors, the BLDC-SL motor does not use mechanical commutator brushes. Eliminating the brushes removes one of the principal wear components of conventional DC motors and significantly improves the suitability of the drive for long-term solar tracker operation. The sensorless design also eliminates the requirement for Hall sensors for motor commutation.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">MOTOR DATA<\/span><\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"302\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Parameter<\/span><\/strong><\/td>\n<td width=\"302\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Specification<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Voltage<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">24 VDC<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">No-load Speed<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">7,000 rpm \u00b110%<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Speed<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">5,100 rpm \u00b110%<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Motor Torque<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">0.07 Nm<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Motor Power<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">38 W<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Motor Current<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">3 A<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Maximum Actuator Motor Current<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">5.3 A<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Motor Type<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">BLDC-SL &#8211; Brushless Sensorless DC<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">6. WHY BLDC-SL?<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">NO MECHANICAL BRUSHES<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">No brush wear and no requirement for periodic brush replacement.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">SENSORLESS OPERATION<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">No Hall sensors are required for motor commutation, reducing the number of internal electronic components and potential failure points, due to EMC induced fault signals to encoder or\/and bad conections of small wires to encoder.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">HIGH DUTY-CYCLE CAPABILITY<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The BLDC-SL drive provides substantially improved thermal endurance and duty-cycle capability compared with the previous brushed DC motor generation.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">HIGH TRANSIENT LOAD CAPABILITY<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The motor provides substantial short-duration drive reserve, particularly valuable when the tracker must move under increased wind loading.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">REDUCED MAINTENANCE REQUIREMENTS<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Elimination of mechanical motor brushes reduces wear-related maintenance requirements.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">LONG-TERM OUTDOOR OPERATION<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The drive concept is particularly suitable for solar tracking systems where reliability, long service life and the ability to withstand changing environmental loads are critical.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">7. HIGH-DUTY OPERATION RATED DUTY CYCLE: 60%<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The BLDC-SL drive is designed for high-duty intermittent operation. The specified 60% Rated Duty Cycle intentionally provides additional thermal operating reserve for variations in mechanical load, ambient temperature, installation conditions and individual component tolerances. Duty cycle applies only while the motor is actively driven.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Static holding with the motor de-energized is not included in the motor duty cycle.<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">HIGH-DUTY TESTED<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The BLDC-SL drive has successfully completed high-duty testing under high-load \/ maximum-power operating conditions with the following cycle:<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">30 seconds ON \/ 6 seconds OFF<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">corresponding to:<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">83.3% DUTY CYCLE<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The actuator performed successfully under these demanding test conditions. For the production specification, the Rated Duty Cycle is intentionally limited to:<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">60% providing additional thermal and operational reserve.<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">8. INTELLIGENT MOTOR PROTECTION &amp; CURRENT MONITORING WITH SAT CONTROL POSITIONERS<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">When operated with the SAT CONTROL solar positioner, the BLDC-SL actuator benefits from continuous motor-current monitoring during actuator movement. The positioner continuously monitors the electrical load of the actuator motor. Correctly configured current limits allow the control system to detect abnormal operating conditions and excessive mechanical loading before they develop into prolonged motor overload. The protection system can provide:<\/span><\/p>\n<ul>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Continuous motor-current monitoring<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Adjustable current limitation<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Overcurrent detection<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Motor overload detection<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Calculated thermal \/ overheating protection<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Alarm generation<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Protection against prolonged excessive motor loading<\/span><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Protection parameters must be correctly configured according to the actuator version and application.<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">NORMAL OPERATING REGION<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Operating Thrust<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The actuator normally operates within its rated load and normal current range.<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">TRANSIENT HIGH-LOAD REGION<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak Dynamic Thrust<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">During short-duration transient loading, such as rapidly increasing wind load, the actuator can temporarily operate in the Peak Dynamic Thrust region. Motor current is continuously monitored by the SAT CONTROL positioner.<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">OVERLOAD REGION<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Current + Time Monitoring<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">If excessive loading continues, current and time-based protection can detect the abnormal operating condition and initiate the configured protective response and alarm.<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">STATIC HOLDING<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Up to 25 kN \/ 2,550 kgf<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Once movement is completed, the motor can be de-energized. The mechanical actuator can then maintain the stationary load without continuous motor power consumption or motor heating.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">9. SYSTEM-LEVEL PROTECTION<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The combination of:<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">High mechanical static holding capacity<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">High-duty BLDC-SL drive<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">High transient dynamic thrust<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Continuous motor-current monitoring<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Adjustable current limitation<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Motor overload protection<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Calculated thermal protection<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Provides substantial operating reserve without requiring the actuator motor to be continuously dimensioned for extreme transient loads.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">10. HEAVY-DUTY TRAPEZODIAL SPINDLE SYSTEM<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Linear movement is generated by a robust trapezoidal spindle transmission.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">SPINDLE<\/span><\/strong><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Manufacturing:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> Rolled trapezoidal thread according to DIN 103<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Material:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> Stainless steel<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Lead:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> 4 mm<\/span><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">SPINDLE NUT<\/span><\/strong><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Lead:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> 4 mm<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Material:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> Bronze<\/span><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The bronze spindle nut provides a robust sliding pair suitable for high mechanical loading and long-term outdoor actuator operation.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">11. HIGH-PERFORMANCE LUBRICATION<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">TOTAL CERAN XS 40 MOLY<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The spindle transmission is lubricated with a high-performance synthetic calcium sulfonate complex grease containing 5% MoS\u2082, selected for demanding heavy-duty operation.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"302\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Characteristic<\/span><\/strong><\/td>\n<td width=\"302\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Value<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Operating Temperature<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">-60\u00b0C to +135\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">NLGI Grade<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">1-2<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">MoS\u2082 Content<\/span><\/td>\n<td width=\"302\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">5%<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The lubricant provides high extreme-pressure performance and is suitable for high mechanical loads, shock loads and demanding environmental conditions.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">12. MECHANICAL STRENGTH<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The SM4 actuator architecture has been subjected to mechanical tensile and compression strength testing. During mechanical testing of a previous SM4 actuator construction, the first force-drop event occurred at approximately:<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">TENSION: 37.8 kN<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">COMPRESSION: 50.2 kN<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The current specified: <\/span><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">MAXIMUM STATIC HOLDING LOAD: 25 kN \/ 2,550 kgf<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">therefore remains below the measured structural strength of the tested actuator construction. The current actuator incorporates equivalent or improved load-bearing components compared with the previously tested construction. Mechanical strength test values represent structural test results and shall not be interpreted as motor-driven thrust capability.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">13. OUTDOOR-OPTIMIZED CONSTRUCTION<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">The SM4 actuator has been specifically designed for long-term outdoor operation in solar tracker applications. The external and internal construction uses corrosion-resistant materials in critical areas. Drainage openings are incorporated into the actuator design to allow condensation or occasional internal moisture to drain naturally from the actuator. The internal mechanical arrangement is designed so that occasional moisture entering the actuator does not interfere with normal mechanical operation. The actuator construction therefore does not rely exclusively on preventing every possible occurrence of internal condensation, but also provides controlled drainage and moisture-tolerant internal construction. Pressure equalization can additionally be incorporated to reduce pressure variations caused by temperature changes and changing atmospheric pressure.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">14. WHY STATIC HOLDING CAPACITY MATTERS<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">For a solar tracker actuator, maximum motor thrust alone does not describe the actual capability of the actuator. During most of its operating life, the tracker is stationary. The actuator must therefore primarily provide reliable mechanical holding capability against external loads while requiring little or no motor power.<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">NORMAL MOVEMENT<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">2.45 &#8211; 5.39 kN Rated Operating Thrust <\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">depending on gearbox version.<\/span><\/p>\n<ul>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"><strong>TRANSIENT MOVEMENT UNDER HIGH LOAD<\/strong><\/span><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Up to 19.94 kN Peak Dynamic Thrust <\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">depending on gearbox version.<\/span><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">STATIONARY STRUCTURAL HOLDING<\/span><\/strong><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Up to 25 kN Static Holding Load<\/span><\/strong><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">This provides a high mechanical load reserve while avoiding unnecessary motor power consumption during stationary operation.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span style=\"color: #008ccd\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">15. APPLICATION SELECTION GUIDE<\/span><\/strong><\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">R188 &#8211; HIGHER SPEED<\/span><\/strong><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Operating Thrust: <\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">250 kgf \/ 2.45 kN<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Max Power Dynamic Thrust:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> 500 kgf \/ 4.90 kN<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak Dynamic Thrust: <\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">9.41 kN \/ 960 kgf<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Approx. Rated Speed:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> 1.80 mm\/s<\/span><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Recommended where higher movement speed is preferred and lower dynamic thrust is sufficient.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">R369 &#8211; BALANCED<\/span><\/strong><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Operating Thrust: <\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">400 kgf \/ 3.92 kN<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Max Power Dynamic Thrust:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> 800 kgf \/ 7.85 kN<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak Dynamic Thrust:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> 14.51 kN \/ 1480 kgf<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"><strong>Approx. Rated Speed:<\/strong> <\/span><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">0.92 mm\/s<\/span><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Recommended for applications requiring a balanced combination of movement speed and available thrust.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">R516 &#8211; HIGH THRUST<\/span><\/strong><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Operating Thrust: <\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">550 kgf \/ 5.39 kN<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Max Power Dynamic Thrust:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> 1,100 kgf \/ 10.79 kN<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak Dynamic Thrust:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> 19.94 kN \/ 2034 kgf<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Approx. Rated Speed: <\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">0.66 mm\/s<\/span><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Recommended where maximum available dynamic thrust is the primary requirement.<\/span><\/p>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">ALL THREE VERSIONS<\/span><\/strong><\/p>\n<ul>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Maximum Static Holding Load<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">25 kN \/ 2,550 kgf<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Duty Cycle<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">60%<\/span><\/strong><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Supply Voltage:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> 24 VDC<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Motor:<\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"> BLDC-SL Sensorless Brushless DC<\/span><\/li>\n<li><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Motor Current Monitoring: <\/span><\/strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Available with SAT CONTROL positioner<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"><strong>Motor Overload Protection:<\/strong> <\/span><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Available with correctly configured SAT CONTROL positioner<\/span><\/li>\n<\/ul>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-start\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\" style=\"color: #008ccd\">IMPORTANT OPERATING NOTES<\/span><\/strong><\/p>\n<ol>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Operating Thrust represents the recommended load range for normal repetitive actuator operation.<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak Dynamic Thrust represents short-duration capability for transient conditions and shall not be used as the normal or continuous operating point.<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Maximum Static Holding Load applies to the stationary actuator and does not represent available motor-driven thrust.<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Static holding with the motor de-energized does not contribute to motor duty cycle or motor heating.<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Rated Duty Cycle is 60% for intermittent motor operation.<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Peak dynamic operation must be limited in duration and should be supervised by correctly configured motor-current and overload protection.<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Current limits and thermal protection parameters must be correctly configured according to the actuator version, application and expected operating conditions.<\/span><\/li>\n<li><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">Structural strength test values are not equivalent to permissible motor-driven operating loads.<\/span><\/li>\n<\/ol>\n<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-start\"><strong><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">SM4 BLDC-SL | HEAVY-DUTY SOLAR TRACKER ACTUATOR | 25 kN STATIC HOLDING CAPACITY | 60% RATED DUTY CYCLE | SENSORLESS BRUSHLESS DRIVE | HIGH TRANSIENT THRUST RESERVE | INTELLIGENT CURRENT MONITORING &amp; MOTOR PROTECTION | ENGINEERED FOR SOLAR TRACKING<\/span><\/strong><\/p>\n<p><span style=\"color: #008ccd\"><strong>Documentation:<\/strong><\/span><\/p>\n<p><a href=\"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/SM4-BLDC-SL-HEAVY-DUTY-SOLAR-TRACKER-ACTUATOR-3.pdf\">SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p class=\"cvGsUA block-font-kerning-normal block-font-feature-liga-off block-font-feature-clig-off block-font-feature-calt-off direction-ltr align-justify\"><span class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\">SM4 BLDC-SL | HEAVY-DUTY SOLAR TRACKER ACTUATOR | 25 kN STATIC HOLDING CAPACITY | 60% RATED DUTY CYCLE | SENSORLESS BRUSHLESS DRIVE | HIGH TRANSIENT THRUST RESERVE | INTELLIGENT CURRENT MONITORING &amp; MOTOR PROTECTION | ENGINEERED FOR SOLAR TRACKING<\/span><\/p>\n","protected":false},"featured_media":10777,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false},"product_brand":[],"product_cat":[43,37,36,25],"product_tag":[],"class_list":{"0":"post-10769","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-dual-axis-sun-trackers","7":"product_cat-linear-motors","8":"product_cat-linear-motors-actuators","9":"product_cat-solar-trackers","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"purchasable","16":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR (0094-23) - Solar Motors<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR (0094-23) - Solar Motors\" \/>\n<meta property=\"og:description\" content=\"SM4 BLDC-SL | HEAVY-DUTY SOLAR TRACKER ACTUATOR | 25 kN STATIC HOLDING CAPACITY | 60% RATED DUTY CYCLE | SENSORLESS BRUSHLESS DRIVE | HIGH TRANSIENT THRUST RESERVE | INTELLIGENT CURRENT MONITORING &amp; MOTOR PROTECTION | ENGINEERED FOR SOLAR TRACKING\" \/>\n<meta property=\"og:url\" content=\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/\" \/>\n<meta property=\"og:site_name\" content=\"Solar Motors\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-28T22:05:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/SM4-BLDC-SL-HEAVY-DUTY-SOLAR-TRACKER-ACTUATOR.png\" \/>\n\t<meta property=\"og:image:width\" content=\"394\" \/>\n\t<meta property=\"og:image:height\" content=\"138\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"11\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/\",\"url\":\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/\",\"name\":\"SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR (0094-23) - Solar Motors\",\"isPartOf\":{\"@id\":\"https:\/\/solar-motors.com\/de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/SM4-BLDC-SL-HEAVY-DUTY-SOLAR-TRACKER-ACTUATOR.png\",\"datePublished\":\"2026-09-22T11:08:17+00:00\",\"dateModified\":\"2026-09-28T22:05:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#primaryimage\",\"url\":\"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/SM4-BLDC-SL-HEAVY-DUTY-SOLAR-TRACKER-ACTUATOR.png\",\"contentUrl\":\"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/SM4-BLDC-SL-HEAVY-DUTY-SOLAR-TRACKER-ACTUATOR.png\",\"width\":394,\"height\":138},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/solar-motors.com\/de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/solar-motors.com\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR (0094-23)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/solar-motors.com\/de\/#website\",\"url\":\"https:\/\/solar-motors.com\/de\/\",\"name\":\"Solar Motors\",\"description\":\"Dependable Sun Tracking Systems Since 2005\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/solar-motors.com\/de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR (0094-23) - Solar Motors","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/","og_locale":"de_DE","og_type":"article","og_title":"SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR (0094-23) - Solar Motors","og_description":"SM4 BLDC-SL | HEAVY-DUTY SOLAR TRACKER ACTUATOR | 25 kN STATIC HOLDING CAPACITY | 60% RATED DUTY CYCLE | SENSORLESS BRUSHLESS DRIVE | HIGH TRANSIENT THRUST RESERVE | INTELLIGENT CURRENT MONITORING &amp; MOTOR PROTECTION | ENGINEERED FOR SOLAR TRACKING","og_url":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/","og_site_name":"Solar Motors","article_modified_time":"2026-09-28T22:05:04+00:00","og_image":[{"width":394,"height":138,"url":"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/SM4-BLDC-SL-HEAVY-DUTY-SOLAR-TRACKER-ACTUATOR.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"11\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/","url":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/","name":"SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR (0094-23) - Solar Motors","isPartOf":{"@id":"https:\/\/solar-motors.com\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#primaryimage"},"image":{"@id":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#primaryimage"},"thumbnailUrl":"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/SM4-BLDC-SL-HEAVY-DUTY-SOLAR-TRACKER-ACTUATOR.png","datePublished":"2026-09-22T11:08:17+00:00","dateModified":"2026-09-28T22:05:04+00:00","breadcrumb":{"@id":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#primaryimage","url":"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/SM4-BLDC-SL-HEAVY-DUTY-SOLAR-TRACKER-ACTUATOR.png","contentUrl":"https:\/\/solar-motors.com\/wp-content\/uploads\/2026\/09\/SM4-BLDC-SL-HEAVY-DUTY-SOLAR-TRACKER-ACTUATOR.png","width":394,"height":138},{"@type":"BreadcrumbList","@id":"https:\/\/solar-motors.com\/de\/produkt\/sm4-bldc-sl-heavy-duty-solar-tracker-actuator\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/solar-motors.com\/de\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/solar-motors.com\/shop\/"},{"@type":"ListItem","position":3,"name":"SM4 BLDC-SL HEAVY-DUTY SOLAR TRACKER ACTUATOR (0094-23)"}]},{"@type":"WebSite","@id":"https:\/\/solar-motors.com\/de\/#website","url":"https:\/\/solar-motors.com\/de\/","name":"Solar Motors","description":"Dependable Sun Tracking Systems Since 2005","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/solar-motors.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"}]}},"_links":{"self":[{"href":"https:\/\/solar-motors.com\/de\/wp-json\/wp\/v2\/product\/10769","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/solar-motors.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/solar-motors.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/solar-motors.com\/de\/wp-json\/wp\/v2\/comments?post=10769"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/solar-motors.com\/de\/wp-json\/wp\/v2\/media\/10777"}],"wp:attachment":[{"href":"https:\/\/solar-motors.com\/de\/wp-json\/wp\/v2\/media?parent=10769"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/solar-motors.com\/de\/wp-json\/wp\/v2\/product_brand?post=10769"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/solar-motors.com\/de\/wp-json\/wp\/v2\/product_cat?post=10769"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/solar-motors.com\/de\/wp-json\/wp\/v2\/product_tag?post=10769"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}